FR3-01A-R1, bath room and laundry Fan control favourite.

A$217.00

Delay off timer & 5 amp relay for remote input socket for controlled load.

The ABC FR3-01A-R is designed so there is no internal wiring termination needed it will switch on when a signal is received from the monitored circuit via a remote current sensor or switch source, once the sorce is turned off and the adjustable run on timer has cycled the relay will turn off . This version is especially made with high current monitoring such as driers, cook tops etc.When monitoring the power to lights, fans, dryer, GPO or a range hood the ABC FR3-01A-R unit can be used to operate a secondary fan such as a booster fan or fresh air fan or even a damper motor. In the example shown below by using a remote connected C1200 current sensor the fan will operate when the dryer used more than .2 amps and will continue to operate unit the dryer current drops below .2 amps is turned off. NOTE. If your drier or current source has a higher standby current we suggest using the adjustable C1220. if the circuit to be monitored has a running current down to .1 amps we suggest wrapping the wire being monitored around the CT twice . If the monitored circuit is below .1 amps such as a single LED down Light we suggest using the C1300, this allows the monitored wire to be wrapped up to 5 times around the current sensor giving a very low current triggering

Quantity:
Add To Cart

Delay off timer & 5 amp relay for remote input socket for controlled load.

The ABC FR3-01A-R is designed so there is no internal wiring termination needed it will switch on when a signal is received from the monitored circuit via a remote current sensor or switch source, once the sorce is turned off and the adjustable run on timer has cycled the relay will turn off . This version is especially made with high current monitoring such as driers, cook tops etc.When monitoring the power to lights, fans, dryer, GPO or a range hood the ABC FR3-01A-R unit can be used to operate a secondary fan such as a booster fan or fresh air fan or even a damper motor. In the example shown below by using a remote connected C1200 current sensor the fan will operate when the dryer used more than .2 amps and will continue to operate unit the dryer current drops below .2 amps is turned off. NOTE. If your drier or current source has a higher standby current we suggest using the adjustable C1220. if the circuit to be monitored has a running current down to .1 amps we suggest wrapping the wire being monitored around the CT twice . If the monitored circuit is below .1 amps such as a single LED down Light we suggest using the C1300, this allows the monitored wire to be wrapped up to 5 times around the current sensor giving a very low current triggering

Delay off timer & 5 amp relay for remote input socket for controlled load.

The ABC FR3-01A-R is designed so there is no internal wiring termination needed it will switch on when a signal is received from the monitored circuit via a remote current sensor or switch source, once the sorce is turned off and the adjustable run on timer has cycled the relay will turn off . This version is especially made with high current monitoring such as driers, cook tops etc.When monitoring the power to lights, fans, dryer, GPO or a range hood the ABC FR3-01A-R unit can be used to operate a secondary fan such as a booster fan or fresh air fan or even a damper motor. In the example shown below by using a remote connected C1200 current sensor the fan will operate when the dryer used more than .2 amps and will continue to operate unit the dryer current drops below .2 amps is turned off. NOTE. If your drier or current source has a higher standby current we suggest using the adjustable C1220. if the circuit to be monitored has a running current down to .1 amps we suggest wrapping the wire being monitored around the CT twice . If the monitored circuit is below .1 amps such as a single LED down Light we suggest using the C1300, this allows the monitored wire to be wrapped up to 5 times around the current sensor giving a very low current triggering